Quick temperature change test box operation specifications and precautions: 1. The rapid temperature change test chamber is absolutely prohibited from heating or testing explosive, flammable and highly corrosive substances during use. Otherwise it will cause unnecessary losses. Electric Fat Bike,Fat Tire Electric Bike,Fat Tire Electric Bicycle,Fat Tyre Electric Bicycle Wuxi Jiangyin Xufeng Electric Bicycle Co., Ltd. , https://www.xufengrelxrides.com
2. The amount of test object placed does not affect the air volume cycle of the test box, otherwise it will affect the test result.
3. When the stress screening test box is used, the door must be closed, otherwise the warm air will leak out and the test performance will not be achieved.
4. The test box equipment should be operated by designated professional personnel to avoid premature damage or failure of the rapid temperature change test chamber .
5. If the rapid temperature change test box is running below 0 °C, it should be avoided to open the door as much as possible. Because when the temperature is low, if the door is opened, the internal evaporator and other parts will be blocked. The lower the temperature, the condition The more serious, if it must be opened, the time and number of times the door should be opened should be minimized.
6. When the rapid temperature change stress screening test box completes the low temperature operation, be sure to set the temperature condition at 60 ° C for drying for about half an hour and open the door to avoid affecting the measurement time of the next working condition or the icing of the evaporator or The test object is damaged.
7. The test box is in operation, unless it is absolutely necessary, please do not open the door, otherwise it may lead to the following adverse consequences:
a, high temperature gas out of the box, very dangerous!
b, the inside of the box door is still high temperature, causing burns!
c. High temperature air may trigger a fire alarm and cause malfunction!
d. How to open the door of the test box: When the operator opens the door, he must move backwards along the direction of opening the door to prevent a large amount of hot air from rushing out of the machine.
8. Please note that the machine must be grounded safely and reliably, so as to avoid the danger of static induction and equipment shaking!
9. Rapid temperature change test box circuit short circuiter and temperature over temperature protector provide the test products and the operator's safety protection, so please check regularly.